 SYNCHRONOUS EQUIPMENT HIGH IN/OUTPUT FREQUENCY CLOCK/SYNCHRONIZER - SY02-HIPL
SY02-HIPL
Date: January 6, 2004
*
INTRODUCTION
The SY02-HIPL is a high frequency crystal-based PLL synchronizer designed as a module level subsystem for easy incorporation into telecommunication equipment.
*
-
FEATURES
Low jitter output from intrinsically low jitter VCXO or VCSO; One references LVEPECL input up to 800MHz (pre-select frequency value -upon order) One high frequency LVPECL output up to 800MHz with E/D function (pre-select frequency value -upon order) Alarms and status; Provides free running clock output; The unit changes timing modes in response to external events; J-TAG service port for re-programming and servicing; 3.3V DC power supply Small dimensions: 0.96" x 1.050"
*
-
APPLICATIONS
ATM SDH PDH SONET Other telecommunication equipment.
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH IN/OUTPUT FREQUENCY CLOCK/SYNCHRONIZER - SY02-HIPL
ALARM FRS
REF
IN
FR
MUX, FPD, Counters & Logic
LOOP FILTER
OUT
VCXO
OUT
J-TAG PORT
EN OUT
*
DESCRIPTION
The SY02-HIPL is a High Frequency Phase Lock Loop has been designed as a module level subsystem for easy incorporation into telecommunication equipment. The module generates the high frequency (up to 622.08MHz) output from a low jitter VCXO (Crystal Based Oscillator) or VCSO (SAW based oscillators). The output can be disabled externally by setting OUTEN pin high. The SY02-HIPL can be locked to one reference input frequency of 155.52MHz. The module has fast locking time and tolerates reference inputs with different duty cycles. The loop bandwidth is optimized according to used VCXO and wanted output performance. The ALARM output signals monitor the status of the phase loop LOL (Loss of Lock) and LOR (Loss of Reference). If the reference REF IN is absent, the SY02-HIPL will automatically switch to free run mode and FRS output will indicate it. The SMD package dimensions are 0.96x1.050 inch and power supply is 3.3V. - OUTPUT PROGRAMMING
OUTEN 0 1 0 FR 0 X 1 OUTPUT Locked to Reference Output Disabled Free-Run
- ALARM STATES
LOL 0 1 0 LOR 0 0 1 ALARM No alarm 1 1
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH IN/OUTPUT FREQUENCY CLOCK/SYNCHRONIZER - SY02-HIPL *
PIN DESCRIPTION
Name Description
Signal Technology Min VL Typ 0.15 --------Vcc-1.620 0.15 0.15 Vcc-1.620 ----0.15 --------0.15 0.15 --------Vcc-1.620 ----Vcc-1.620 0.3 ------Vcc-1.560 0.3 0.3 Vcc-1.560 ---0.3 -------0.3 0.3 ------Vcc-1.560 ---Vcc-1.560 Max VH/ DC Voltage Min 2.97 ----------Vcc-1.085 2.97 2.97 Vcc-1.085 -----2.97 3.135 -----2.97 2.97 ----------Vcc-1.085 -----Vcc-1.085 Typ 3.3 ----------Vcc-1.025 3.3 3.3 Vcc-1.025 -----3.3 3.3 -----3.3 3.3 ----------Vcc-1.025 -----Vcc-1.025 Max 3.465 ----------Vcc-0.885 3.465 3.465 Vcc-0.885 -----3.465 3.465 -----3.465 3.465 ----------Vcc-0.885 -----Vcc-0.885
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
ENABLE TCK TDO REFA IN SEL RESET REFB IN GND FRS Vcc NC ALARM FR TDI TMS OUT GND OUT
Output Enable - > the input pin to enable the output, active low J-TAG port for factory usage - TCK J-TAG port for factory usage - TDO Reference A Input -> Reference A input signal Select Input Reference -> input to select A (SEL=0) or B (SEL=1) Reset input -> Reset active high In normal operation must be Grounded Reference B Input -> Reference B input signal Ground Free-Run Status -> Output indicates that the module is in free run, active high Positive supply voltage Not Connected Alarm out -> Alarm output indicates loss of reference or loss of lock - High when the unit is Unlocked Free-Run -> Control input to select free run of the module, active high J-TAG port for factory usage - TDI J-TAG port for factory usage - TMS Oscillator Output -> Output of the module Ground Complimentary Output
DC --------LV/PECL DC DC LV/PECL ----DC DC ----DC DC --------LV/PECL ----LV/PECL
0 --------Vcc-1.680 0 0 Vcc-1.680 ----0 --------0 0 --------Vcc-1.680 ----Vcc-1.680
*
ORDERING INFORMATION
o Input/Output Frequencies available; Frequency 112.000MHz 114.000MHz 125.000MHz 133.000MHz 139.264MHz 155.520MHz 156.250MHz 161.1328MHz 166.6286MHz 167.3316MHz 168.0407MHz 175.0000MHz 178.9440MHz 184.3200MHz 311.0400MHz 622.0800MHz 625.000MHz 644.5312MHz 666.5143MHz 669.1281MHz 669.3266MHz 690.5692MHz 710.9486MHz 719.7344MHz Suffix B7 B8 G2 G4 E6 O4 G6 B9 B10 C1 C2 C3 C4 C5 O6 O7 C8 C9 C10 F1 F2 F3 F4 F5 Frequency 777.6000MHz Suffix F6
Frequency Suffix 19.440MHz O1** 20.000MHz M1** 20.1416MHz A3** 20.4800MHz A4** 22.2171MHz A5** 26.0000MHz G3** 27.0000MHz A6** 29.4912MHz A7** 32.768MHz E5** 34.560MHz A8** 37.0560MHz A9** 38.880MHz O2** 44.4343MHz B1** 44.7360MHz T3** 51.8400MHz D2** 61.4400MHz U1** 62.5000MHz G5** 65.5360MHz B2** 77.7600MHz O3 78.125MHz B3 78.6432MHz B4 82.9440MHz B5 92.6000MHz U3 100.000MHz B6 ** Signifies an Input Frequency Only
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH IN/OUTPUT FREQUENCY CLOCK/SYNCHRONIZER - SY02-HIPL P/N System SY02-HIPL - < Input Frequency> -S- -
See above Chart If not listed Place NL and state the Freq.) See above Chart (If Output Freq. Not applied place NA and state the Freq.) Supply Voltage; 4 - 3.3V Operating Temperature Range; C - 0C to 70C I -40C to +85C Cover Option; M - Metal Cover N - Non Covered unit
* SPECIFICATION
General Specifications Mechanical Power Environment Internal Oscillators Number of Reference Inputs Input reference frequency Signal Level Number of Outputs Output 1 Output 1 Signal Level Duty Cycle Tracking/Capture Range Free Run stability Jitter generation 0.96" x 1.050" 3.3VDC, <200mA Operating Temperature Humidity VCXO or VCSO 1 See above table LVPECL 1 See above table LVPECL (W/ Complimentary option) 50+/-10% 50ppm APR min 30ppm (VCXO) 150PPM(VCSO) <0.001UI RMS <0.001UI RMS <0.0001 UI RMS <0.0001 UI RMS -40dB -10dB 2 s, 10 Hz (0.05 UI @ 8KHz) SMT Module FR4 18 pins dual-in-line Regulated 0C to 70C 5% to 95% non-condensing Depend of the frequency
Input Signals
Voh; 2.272V min ; Vol; 1.68Vmax other frequency contact Raltron Voh; 2.272V min ; Vol; 1.68Vmax 50%+/-5% available upon request T=+25C; Vcc/load-=nominal HPF 30Hz HPF 500Hz HPF 12KHz HPF 100KHz Fj=10Hz~1KHz Fj=1KHz~10MHz
Output Signals
Signal Quality Performance
Jitter attenuation Jitter tolerance
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
SYNCHRONOUS EQUIPMENT HIGH IN/OUTPUT FREQUENCY CLOCK/SYNCHRONIZER - SY02-HIPL
* OUTLINE DRAWING
1.040 (26.42 mm) .840 (21.34 mm) .100 (2.54 mm) 1
1.00 (25.40mm) .960 (24.38mm) 18
.865 (21.97 mm)
.065 (1.65 mm) .100 (.2.54 mm)
.035 (.89 mm)
MARKING LABEL
9 10
PCB FOOTPRINT
TOP VIEW
.416 MAX. (10.57mm MAX.
.100 (2.54mm)
SIDE VIEW
TABS
FRONT VIEW
* REFLOW PROFILE
250 200 150 XY (Scatter) 1 100 50 0 0 1 2 3 4 5 6 7 8
RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: sales@raltron.com Internet: http:/www.raltron.com
th
1.050 (26.67mm)
.800 (20.32 mm)
.019 (.48 mm)


▲Up To Search▲   

 
Price & Availability of SY02-HIPL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X